Pipe Pressure Head Loss

 The below table shows friction loss over 30 metres (or 100 feet) of Buteline PB-1 pipe:

Pressure / Head Loss Per 30 Metres (100 Feet) of Pipe
Minimum Flow Required
10mm 16mm 22mm 28mm
L/min Bar Bar Bar Bar
0.5 0.036 0.002 - -
1 0.131 0.007 0.001 -
2 0.472 0.026 0.005 0.002
3 1.000 0.055 0.011 0.004
4 1.704 0.094 0.019 0.006
5 2.573 0.141 0.029 0.009
10 - 0.510 0.104 0.034
12 - 0.715 0.146 0.047
14 - 0.950 0.194 0.063
16 - 1.217 0.248 0.080
18 - 1.513 0.309 0.100
20 - 1.839 0.375 0.100
25 - 2.778 0.567 0.183
30 - 3.893 0.795 0.256
35 - 5.177 1.057 0.341
40 - 6.628 1.353 0.437
45 - 8.242 1.628 0.543

 